Dwyer UXF3 Series Features
- High accuracy
- Excellent resistance against aerated flow
- Quick response with high-speed microprocessor
- Multilingual display (English, Japanese, German, French, and Spanish)
- Large type graphic LCD
- Front keypad
Dwyer UXF3 Series Specification
Service | Liquid flow through which ultrasonic signal can be transmitted (water, sea water, oil, and fluid of unknown velocity). |
Inputs | Sensor cable radio frequency coaxial cable RG-58A/U2. |
Range | 0 to ±105 fps (0 to ±32 m/s) (bi-directional flow). |
Display | LCD with backlight, 16 letters 2 lines. |
Accuracy | ±1.0% of rate. |
Power Requirements | 100 to 240 VAC ±10% 50/60 Hz, or 20 to 30 VDC. |
Power Consumption | AC: 15 VA; DC: 6W. |
Temperature Limits | Ambient -4 to 131°F (-20 to 55°C). |
Output | Analog: 4 to 20 mA DC current output; Digital: One mechanical relay output, 240 VAC, 30 VDC, 1 A. Two transistor outputs available, Open collector output: 30 VDC, 0.1A. |
Serial Communications (option) | RS485. |
Enclosure Rating | NEMA 4X (IP66). |
Material | Aluminum alloy. |
Electrical Connections | Screw terminals. |
Mounting | Wall or pipe mount. |
Weight | 10 lb (4.5 kg). |