Bamo PDP Small Plastic Flow Indicator applies the principle of variable area flow-meter: the flow raises a diver in a conical tube expanding the cross section of fluid passage. The diver moves up proportionally to the flow-rate (diver is commonly named ''float''). Standard equipment includes a graduated scale in l/h of water at 20 °C. In options there are specific scales: Air in Nm³/h; HCl at 30...33 %; NaOH at 30 % & 50 %.
Bamo PDP Small Plastic Flow Indicator |
Bamo PDP Features:
- Direct reading
- All wet parts in plastics
- Materials: PVC, PSU, PVDF, EPDM
- Scales from 2.5 up to 1,000 l/h of water
- Other scales: Air in Nm³/h, HCl and NaOH.
- Option: Adjustable contacts
Precautions for mounting:
Flow indicators must be installed vertically with rising fluid. It is recommended to have a length upstream of 10 x ND and downstream of 5 x ND.
Application:
PDP series are ideally suited for continuous measurement of flow for air and neutral, basic or acidic liquids.
Specification:
Pressure limit | 10 bar max. at 20 °C |
Temperature limits at 1 bar | PVC: 0 ... +50 °C (Water) |
PSU (Polysulfone): 0 ... +90 °C (Max. 60 °C with | |
PVC fittings) | |
PVDF (option) on request | |
Graduated scales | l/h (Standard for water at 20 °C) |
Specific scales | Air in Nm³/h (1 to 9 bar absolute pressure) |
HCl (30 ... 33 %); NaOH (30 % and 50 %) | |
Materials | PVC or PSU (Polysulfone) |
Measuring tubes | |
Diver and stoppers | PVDF |
Seals | EPDM (standard) - FPM in option |
Unions | PVC for solvent welding |
Fittings | Standard: PVC Unions for solvent welding |
Contacts Z42 and Z40 | |
The flow indicator must have a diver with a built-in magnet (PVDF-A) | |
Switching power | Max. 10 W / 12 VA; 230 V AC; 0.5 A |
Operation | Z42: Change-over contact, N.O. without flow |
Z40: Change-over contact, N.C. without flow | |
Protection | IP 65 - Pluggable terminal block |
Ambient temperature | 0... +55 °C |
Download Data Sheet: Small Plastic Flow Indicator PDP
Ref: flux-pumps.com