Bmeters RFM-LR1 Lorawan Radio Module |
- Consumption analysis with reverse flow compensation that provides an always perfect alignment between the counter and the
counter clock. - Fraud control (removal of the radio module, application of external magnetic field, reverse flow, identification of system loss).
- Magnetic tampering at the counter and removal are recorded and reported to the receiving system via radio transmission.
- The presence of reverse flow is recorded in an additional register that allows to calculate the amount of water passed in reverse.
- The loss function can be monitored at the time of reading or by the AMR system if a timely update is desired.
- IP68 protection* allows the use of the module also for meters installed in difficult environments
Bmeters RFM-LR1 Technical Features
Radio interface | LoRaWAN @868 MHz ≤ 25 mW |
Network joining methods | OTAA, on request ABP |
Frequency of transmission | 4 per day |
Coverage | Up to 5 Km* |
Compatible water meters | GSD8-RFM |
Pulse output minimum value (K) | 1 liter |
Configuration | Via downlink commands from LoRa network |
Energy supply | Non-replaceable lithium battery, maximum lifetime 10 years** |
Protection class | IP68*** |
Weight | 84 g |
Size (l x p x h) | 26 x 26 x 13 mm |
Working Temperature | +1° ÷ +55°C |
Transmitted data | Volume (consumption), total of backward flow, alarms |
Alarms | Discharged battery, module removal, magnetic fraud attempt, backward flow, leakage detection |
* In optimal signal transmission conditions;
** The battery life strongly depends on the working time window, set during the configuration process, and on the environmental conditions;
*** IP68: maximum 24 hours of continuous submersion at 1 m depth.
Download Datasheet: Bmeters RFM-LR1 Lorawan Radio module
Reference: bmeters.com