Dinel HLM–35 Hydrostatic level meter |
Dinel HLM–35 Hydrostatic Level Meter Benefit
- Intended for various liquids (water, oil, coolants, water solutions, etc.)
- High long-term stability
- Accuracy 0,5% within the total range
- Measuring range up to 100 m (H2O)
- Thread process connection
- Current or voltage output
- LED indicators
- Variant with an option of settings with a magnetic pen within the selected range
Dinel HLM–35 Hydrostatic level meter Specifications
Working environment (EN 60079-10-1) | no explosive hazard area | |
Supply voltage | HLM–35_–_ _- _- I- _- _ _ _ _ | 12 ... 34 V DC |
HLM–35_–_ _- _- U- _- _ _ _ _ | 12 ... 34 V DC | |
Current output | HLM–35_–_ _- _- I- _- _ _ _ _ | 4 ... 20 mA |
Voltage output | HLM–35_–_ _- _- U- _- _ _ _ _ | 0 ... 10 V |
Consumption (empty voltage output) | HLM–35_–_ _- _- U- _- _ _ _ _ | max. 8 mA |
Permissible overload | 1.5x of range | |
Basic accuracy (non-linearity, hysteresis, repeatability) | 0.5% of range | |
Long-term stability | 0.3 % / year | |
Temperature error for zero and range between | 0 ... +50°C max. 0.04% / K | |
Temperature compensation range | 0 ... +50°C | |
Operating temperature range (temperature of the media) | -20 ... +70 °C | |
Max. load resistance for current output (at U = 24 V DC) | Rmax= 600 Ω | |
Min. load resistance for current output | Rmin= 1 kΩ | |
Protection class | type HLM–35_–_ _- _- _- C- _ _ _ _ | IP67 |
type HLM–35_– _- _- _- (A,B,V,H)- _ _ _ _ | IP68 | |
Cable | type HLM–35_–_ V- _- I- _- _ _ _ _ | PVC 2 x 0.75 mm2 |
type HLM–35_–_ V- _- U- _- _ _ _ _ | PVC 3 x 0.5 mm2 | |
type HLM–35_–_ K- _- I- _- _ _ _ _ | PE 2 x 0.25 mm2 with capillary | |
type HLM–35_–_ K- _- U- _- _ _ _ _ | PE 3 x 0.25 mm2 with capillary | |
Weight sensor | 190 g | |
cable (1 m) | 60 g |
Download Catalog: Hydrostatic level meter HLM–35
Ref: Dinel.cz