Dwyer DS Series In-Line Flow Sensors |
Dwyer DS Series Features
- Multiple sensing point measurement and built-in averaging capability eliminates the need for “traversing” the flowing stream with single point velocity pressure measurement saving time
- Extremely reliable, proven technology, Pitot tubes, have been used in flow measurement for years
- All models include convenient and quick-acting quarter-turn ball valves to isolate the sensor for zeroing with 1/8" female NPT valve assembly process connections.
- Furnished with instrument shut-off valves on both pressure connections with 1/8" female NPT connections rated at 200 psig (13.7 bar) and 200°F (93.3°C)
- Where valves are not required, they can be omitted at reduced cost
- The Series DS-400 Averaging Flow Sensors are quality constructed from extra strong 3/4" dia. stainless steel to resist increased forces encountered at higher flow rates with both air and water
- Economical flow indication when used with appropriate differential pressure gage
- Rugged construction yields, non-clogging, stable design
Application
- Remediation
- Natural, flare, flue, stack gas
- Boiler feedwater
- Cooling water
- Superheated, saturated, or geothermal steam
- Combustion or compressed air
- Oil flow monitoring
Dwyer DS Series Specification
Service | Compatible gases or liquids. |
Wetted Materials | Sensor tube: 304 SS; Compression fitting: brass |
Temperature Limit | 200°F (93.3°C). |
Pressure Limit | 200 psig (13.78 bar) at 200°F (93.3°C). |
Pipe Sizes | DS-300: 1 to 10˝ (2.5 to 25.4 cm); DS-400: 6 to 24˝ (15.2 to 61 cm) |
Process Connections | DS-300: 1/4˝ male NPT compression fitting included; DS400: 3/4˝ male NPT compression fitting included. |
Piping Connections | DS-300: 1/8˝ female NPT; optional 1/8˝ female NPT x 1/4˝ SAE 45 flared adapter sold separately; DS-400: 1/8˝ female NPT with 1/8˝ female NPT x 1/4˝ SAE 45 flared adapters include. |
Weights | Consult factory |
Download Data Sheet: Series DS In-Line Flow Sensors
Ref: dwyer-inst.com