Dwyer IEF Series Adjustable Insertion Electromagnetic Flow Transmitter |
Dwyer IEF Series Features
- Field configurable, integral or remote setup displays (-LCD option or accessory A-IEF-DSP) allow for ultimate flexibility by accommodating a variety of application configurations with one model through multiple display configurations i.e. pipe size, pipe material, liquid type, analog output, pulse/frequency output, alarm outputs, communication outputs, damping, and calibration factor.
- High performance accuracy is maintained through temperature, density or viscosity.
- Setup Wizard and installation tool are simple to use allowing for quick and precise installation.
- Accessory setup kit A-IEF-KIT ensures exact installation application depth with included thickness gage and measuring tape.
- NIST traceable pass/fail verification certificate included standard for Carbon Steel Schedule 40 pipes sized 4" (102 mm), 6" (150 mm), 8" (200 mm), and 10" (250 mm) with high accuracy option; 10" (250 mm) with standard option.
Application
- Boiler feed water
- Chilled water
- Open and closed loop condenser water
- Ground water remediation
- Chemical processing
- Pump protection
- Wastewater
- Mining
Dwyer IEF Series Specification
Service | Compatible clean or dirty non coating, conductive liquids. |
Range | 0 to 20 ft/s (0 to 6 m/s). |
Wetted Materials | Body shaft/fitting: 316SS; Electrodes: 316SS; Electrode cap: Polymer/Polystyrene; O-ring: Silicon. |
Accuracy | High accuracy units: ±0.5% of reading at calibrated velocity; ±1% of reading from 2 to 20 ft/s (0.6 to 6 m/s); ±0.02 ft/s (±0.006 m/s) at < 2 ft/s (0.6 m/s); |
Standard accuracy units: ±1% FS. | |
Temperature Limits | Ambient: -20 to 160°F (-29 to 71°C); Process: 15 to 250°F (-9 to 121°C); Storage: -40 to 185°F (-40 to 85°C). |
Process Connection | 1" NPT or BSPT with accessory full port ball valve options. |
Pressure Limits | 400 psi (27.6 bar) @ 100º F (37.8°C). |
Pressure Drop | < 0.1 psi at 12 ft/s in 4" (101.6 mm) and larger pipe. |
Power Requirements | 12 to 42.4 VDC, .25 A @ 24 VDC; 12 to 36 VAC. |
Display | 2" ( 5.08 cm) x 2" (5.08 cm) graphic LCD with backlight. |
Download Data Sheet: Series IEF Adjustable Insertion Electromagnetic Flow Transmitter
Ref: dwyer-inst.com