Flowmasonic WUF 300 J Portable Ultrasonic Flowmeter - Flow Meter Indonesia - Flow meter air, flowmeter solar, gas, Ultrasonic, Vortex, Electromagnetic

Breaking

Senin, 14 Februari 2022

Flowmasonic WUF 300 J Portable Ultrasonic Flowmeter

 


Flowma WUF 300 J is a full function handle transfer time ultrasonic flow meter. No matter you want to quickly verify the flow reading of another meter or to data log flow system values over an extended time period, the FLOWMA WUF 300 J is the suitable tool.
Flowmasonic WUF 300 J Portable Ultrasonic Flowmeter

The Flowma WUF 300 J portable meter has the clamp on transducers no tapping or cutting is required, just clamp outside of the pipe. The meter can be easily moved and installed in different pipe and convenient to carry site to site.Its portability makes it an excellent choice for measuring flows throughout the plumbing infrastructure to verify sensor, pump and valve performance.Portable ultrasonic flowmeter Flowma WUF 300 J 
Cara Mengoprasikan Portable Flow Meter ultrasonic

Flowma WUF 300 J Feature

  • Easy to install, reduced installation time and cost.
  • No pressure head loss, No moving parts to maintain or replace.
  • BTU function is an option. WUF 300 J could be used as a portable ultrasonic energy meter.
  • Powerful data storage and also support the data sheet analysis software.

Application

WUF 300 J portable ultrasonic flow meter widely application in oil industry, water treatment, pure water, chemical and etc.

Measuring Principle

Transfer time technical means the ultrasonic signal from the transducer is transmitted and received through the moving liquid, there will be a difference between the upstream and downstream transit time, which can be used to calculate flow and velocity.

Insatallation Ultrasonic transducer flow meter 
Clamp on Ultrasonic transducer Installation

An ultrasonic meter equipped with heat flow capabilities measures the rate and quantity of heat delivered or removed from devices such as heat exchangers. By measuring the volumetric flow rate of the heat exchanger liquid, the temperature at the inlet pipe and the temperature at the outlet pipe, the energy usage can be calculated.

Flowma WUF 300 J Specification

Performance specifications

Velocity±0.03 ft/s ~ ±40 ft/s (±0.01 m/s~ ±12 m/s)
Accuracy±1% of measured value
Pipe sizeClamp-on: 1"~48"(25mm~1200mm)
FluidFluid Single medium liquid
Pipe materialCarbon steel,stainless steel,PVC and other compact material pipe

Function specifications

OutputsAnalog output: 4~20mA, Max 750 Ω.
Modbus: RS485
SD card16GB
Interval1 ~ 99999 seconds
Key broadDigital keys
Display240*128 back lit LCD
Power supplyRechargeable Lithium Battery Power,3000mAh
(Continuous operation of main battery 16 hours).
TemperatureTransmitter: -40℃~60℃
Transducer: -40℃~80℃ (-40℃~80℃ is standard; -40℃~130℃ is an option)
HumidityUp to 99% RH,non-condensing


Physical specifications

TransmitterNEMA13,IP54.
TransducerEncapsulated design,IP68
Transducer cableStandard cable length: 5m (16ft).