| Hengesbach Magnetic-inductive Flow Meter Volumtec |
Hengesbach Magnetic-inductive Flow Meter Volumtec Features:
- Construction according to hygienic design standards, all - stainless steel, protection class IP 67
- Nominal diameter: DN10 - DN150 flow range: 20 l/h - 640 m³/h
- Pressure range: 0,1 - 11 bar abs. accuracy: typ ±0,25 %
- Measurement in both flow directions
- Pulse- and analog output 4-20 mA, active or passive
- Adjustability of the illuminated LC-Display
- Self-monitoring and, if necessary, automatically readjusting electronics
- Process sonnection: aseptic-flange with modular connection system for pipe adapters
Specification:
| General information | ||
| Device type | VOLUMTEC magnetic-inductive flow-measuring device for liquid media | |
| Input | ||
| Flow range | 30l/h … 640m³/h (depending on the nominal diameter) | |
| Pressure range | 0.1 … 11bar abs. (PN 10) | |
| Control input | 3…32V DC, Ri < 3,2 kΩ | |
| Output | ||
| Flow output | 0/4…20mA, active or passive, load max. 500Ω | |
| Impulse output (volume) | 2x opto-coupler, 24 V / 20mA, max. 1000Hz | |
| Status output | Opto-coupler, ready, fault, direction | |
| Measuring accuracy | ||
| Typical accuracy | ± 0.20% FS | |
| Conditions for use | ||
| Medium temperature | Compact: 0…100°C permanent temperature, 130°C max. for 30 minutes | |
| Separate: 0…120°C permanent temperature | ||
| Environmental temperature | -25 … + 55°C | |
| Storage temperature | -25 … + 55°C | |
| Minimum conductivity medium | Compact version ≥ 5µS/cm | |
| Separate version ≥ 15µS/cm, or see connection cable | ||
| Upstream | ≥ 5 x DN | |
| Downstream | ≥ 3 x DN | |
| Protection class EN 60529 | IP67, standard | |
| Grounding resistance | < 10Ω | |
| Electromagnetic compatibility | according to EMC Directive 2004/108/EC | |
| Design configuration | ||
| Process connection | modular connection system with aseptic collar flange according to DIN11864-2 Form A | |
| Process connection adapter | welded necks for pipes according to DIN 11850 , threaded necks and conical connections | |
| with grooved union nut according to DIN11851, clamp, etc. | ||
| Materials for compact and separate version | housing: | 304 |
| in contact with product: | Electrodes 316L | |
| PFA measuring pipe lining (FDA) | ||
| seal: | on process side: EPDM (FDA) | |
| Surface roughness | housing Ra ≤ 2.5µm | |
| measuring pipe lining Ra ≤ 0.8µm | ||
| Nominal diameter | DN10 … DN150 | |
| electrical connection | 3x cable clamp M16x1,5 | |
| Connection cable for separate version | shielded cable: 2x0,5mm² F-CYOZ, 4x0,5mm² LIYCY-0 | |
| Display | graphics LCD display 46 x 23 mm, illuminated | |
| Longer connection cable for separate version | ||
| max. 5m | conductivity from 15-50µs/cm | |
| max. 20m | conductivity from 50-200µs/cm | |
| max. 50m | conductivity from > 200µs/cm | |
| Auxiliary energy | ||
| Supply voltage | DC version: 9…32V DC | |
| AC version: 100…240V AC, 50…60 Hz | ||
| Power input | 7W | |
| Configuration interfaces | ||
| Interface | CS3-BUS / RS485 | |
| Fieldbus | PROFIBUS DP | |
| Radio connection | Bluetooth | |
| Class 2 | ||
Download Data Sheet: Magnetic-inductive flow meter Volumtec
Ref: hengesbach.com