Kamis, 14 April 2022

Kobold DPM Rotating Vane Flow Meter

The KOBOLD model DPM Rotating Vane flowmeters are used for measuring and monitoring liquids. Due to its compact construction the measuring instrument is suitable for use with machines with minimum available space. The system can be used in a wide variety of applications because the output pulses can be analysed in many different ways.
Kobold DPM Rotating Vane Flow Meter

Areas of Application

  • Low viscosity liquids
  • Non-conductive liquids
  • Volume dosing with external electronics
  • Filter aid

 

Kobold DPM Rotating Vane Flowmeters 
Pulse Output DPM-..F5

Measuring range: 0.015 - 0.3 ... 0.05 - 5 l/min water
Connection: G ⅛, G ¼, ⅛" NPT, ¼" NPT
Material: brass nickle plated, stainless steel
pmax: 16 bar
tmax: 80°C
Accuracy: ±1 (±2.5) % of full scale
Pulse output

 

Kobold DPM Rotating Vane Flowmeters 
Analogue Output DPM-..L3

Measuring range: 0.015 - 0.3 ... 0.05 - 5 l/min water
Connection: G ⅛, G ¼, ⅛" NPT, ¼" NPT
Material: brass nickle plated, stainless steel
pmax: 16 bar
tmax: 80°C
Accuracy: ±1 (±2.5) % of full scale
Analogue output

Kobold DPM Rotating Vane Flowmeters 
Analogue Output DPM-..L4 with AUF

Measuring range: 0.015 - 0.3 ... 0.05 - 5 l/min water
Connection: G ⅛, G ¼, ⅛" NPT, ¼" NPT
Material: brass nickle plated, stainless steel
pmax: 16 bar
tmax: 80°C
Accuracy: ±1 (±2.5) % of full scale
Analogue output, digital indicator

 

 

Kobold DPM Rotating Vane Flowmeters 
Rotating Vane Flowmeter DPM

Measuring range: 0.015 - 0.3 ... 0.05 - 5 l/min water
Connection: G ⅛, G ¼, ⅛" NPT, ¼" NPT
Material: brass nickle plated, stainless steel
pmax: 16 bar
tmax: 80°C
Accuracy: ±1 (±2.5) % of full scale
Pulse output, analogue output, contacts,
digital / pointer indicator

 

Kobold DPM Rotating Vane Flowmeters 
Compact Electronic DPM-..C3

Measuring range: 0.015 - 0.3 ... 0.05 - 5 l/min water
Connection: G ⅛, G ¼, ⅛" NPT, ¼" NPT
Material: brass nickle plated, stainless steel
pmax: 16 bar
tmax: 80°C
Accuracy: ±1 (±2.5) % of full scale
Analogue output, contacts NPN / PNP, digital indicator

 Kobold DPM Rotating Vane Flowmeters 

Counter DPM with ZED

Measuring range: 0.015 - 0.3 ... 0.05 - 5 l/min water
Connection: G ⅛, G ¼, ⅛" NPT, ¼" NPT
Material: brass nickle plated, stainless steel
pmax: 16 bar
tmax: 80°C
Accuracy: ±1 (±2.5) % of full scale
Analogue output, totaliser, contacts, digital indicator


Specifications

Technical Details

  • Accuracy:
    DPM..000, F300: ± 2.5% of full scale
    DPM...F390,
    DPM...L, DPM..C: ± 1% of full scale
  • Linearity: 1% of full scale
  • Repeatability: 0.5%
  • Medium temperature: -40...+80°C
  • Ambient temperature: -30...+60°C
  • Max. operating pressure: 16 bar
  • Protection: IP 65

Materials

  • Housing: brass nickel-platedstainless steel 1.4404
  • Upper part: brass nickel-plated stainless steel 1.4404
  • Union nut: brass nickel-plated or stainless steel 1.4305
  • Orifice: 1.4404
  • Axle: sapphire
  • Rotating vane: polypropylene
  • Vane mount: polysulfone
  • Gasket: NBR (standard), FPM or EPDM (optional)

Operating Principles

The medium flows through a specially shaped flow housing and causes a vane to rotate. This rotary motion is sensed by optoelectronics in a non-contacting manner, and converted to an asymmetric frequency signal or an analogue signal. A frequency divider with symmetrical output is available as an option. The frequency is proportional to the flow velocity. The vane is sapphire-supported: this ensures a high degree of linearity and long service life.

Electronics

Frequency output (OEM without CE-Sign)

  • Power supply: 4.5 - 12 VDC
  • Supply current: typ. 7 mA
  • Signal amplitude high: approx. power supply
  • Signal amplitude low: ≤ 0.2 V
  • Transmitter cut-off voltage: 3 V max.
  • Transmitter supply current: 8 - 12 mA
  • Output loss: max. 2.5 mWatt
  • Electrical connection: solder pins
  • Pulse output: NPN, Open Collect., max.10 mA

Frequency output (option frequency divider)

  • Power supply: 24 VDC ±20%
  • Supply current: 40 - 50 mA
  • Signal amplitude high: approx. power supply
  • Signal amplitude low: ≤ 0.2 V
  • Output loss: max. 2.5 mWatt
  • Electrical connection: plug M12x1 (option: 2 m PVC cable)
  • Division ratio (option): 1...1⁄128 factory set
  • Pulse output: PNP, open collector, max. 20 mA

Analogue output (option plug-on display)

  • Power supply: 24 VDC ±20%
  • Output: 0-20 mA or 4-20 mA, 3-wire technology
  • Max. load: 500 Ω
  • Electrical connection: plug connector M12x1 or DIN 43 650
  • Option: plug-on display (with plug connector DIN 43 650 only)

Compact electronics

  • Display: 3-position LED
  • Analogue output: (0)4...20 mA adjustable, max. 500 Ω
  • Switching outputs: 1 (2) semiconductor PNP or NPN, set at the factory
  • Contact operation: programmable N/C/ N/O contact
  • Setting: via 2 buttons
  • Power supply: 24 VDC ±20%, approx. 100 mA, 3-wire technology
  • Electrical connection: plug connector M12x1

Download Datasheet: Kobold DPM Rotating Vane Flowmeters

Reference : kobold.com

Contact

Talk to us

Lorem ipsum dolor sit amet, consectetur adipisicing elit. Dolores iusto fugit esse soluta quae debitis quibusdam harum voluptatem, maxime, aliquam sequi. Tempora ipsum magni unde velit corporis fuga, necessitatibus blanditiis.

Address:

9983 City name, Street name, 232 Apartment C

Work Time:

Monday - Friday from 9am to 5pm

Phone:

595 12 34 567

Diberdayakan oleh Blogger.

Connect With us

Recent News

About Me

authorHello, my name is Jack Sparrow. I'm a 50 year old self-employed Pirate from the Caribbean.
Learn More →

Cari Blog Ini

Product

Technology

News

Sports

Author Details

Templatesyard is a blogger resources site is a provider of high quality blogger template with premium looking layout and robust design. The main mission of templatesyard is to provide the best quality blogger templates which are professionally designed and perfectlly seo optimized to deliver best result for your blog.

Fashion

Food

Videos

Recent

Food

Comments

Pages

Breaking

Pages