Guided Wave Radar Open Channel Flow Meter
Features & Benefits
- Revolutionary TDR Technology
- High accuracy (+/- 0.12mm) with NO moving parts
- Dead Band (Top & Bottom) 1.5”
- Probe guided radar impulses for ease of flow measurement in narrow channels
- Isolated 4-20 mA, 4 10A relay outputs and 1 PNP transistor output plus RS-485 Serial communication, and Ethernet communication
- 6 digit red LED display with touch screen interface and remote monitoring/configuration software (included)
Specifications
Electrical Specifications |
Measuring Range [M] | Probe length [L] less both inactive areas at top and bottom [l1 and l2] in this range Tracer 1000™ will have the specified measurement performance. It is recommended that the maximum and minimum liquid levels to be measured are within the measuring range [M] of the sensor. | |||
Output Functions | Continuous level measurement through analog output and point level detection through switching output. | ||||
Analog Output (Active) | Current output 4-20mA: The span between the lower range value [4mA] and the upper range value [20mA] is equal to 0-100% of the continuous level measurement reading. It is recommended that the span between those two range values stays within the measuring range [M]. | ||||
Application Specifications | |||||
Dielectric Constant [ɛr] |
316 SS Rod: > 1.8 | ||||
Conductivity | No restrictions | ||||
Total Load Resistance | < 500Ω: HART resistor approx. 250Ω + load resistance approx. 250Ω if the current output is connected to a device with an inner resistance of approx. 250Ω, then there is no additional, external HART resistor necessary. In that case, the HART modem is connected in parallel to the current output wires. | Density | No restrictions | ||
Dynamic Viscosity | 316 SS Rod: < 5.00mPa s = 5.000cP | ||||
Standard Application Temp. | F: -40º to 302º C: -40 to 150º | ||||
Ambient Temperature | F: -13º to 176º C: -25º to 80º | ||||
Application Pressure | -14.50 PSI to 580 PSI | ||||
Lower Range Value | 4.0mA (span 0%) | ||||
Upper Range Span | 20.0mA (span 100%) | Velocity of Level Change |
< 3.2 fps | ||
Response Time | 0.5s (default), 2s 5s (selectable) | ||||
Interface (i.e. oil on top of water) | An oil layer of < 2.8” thickness on top of water is not detected by the sensor; in this case the sensor will detect only the water level at a slightly lower position than actual. From an oil layer thickness > 2.8” onwards, the sensor detects the total level, including the oil layer, according to specifications. | ||||
Temperature Drift | Less than .0078 in/ºF change in ambient temperature | ||||
Switching Output DC PNP (Active) | NC (default) or NO (short-circuit protected) | ||||
Load Current | < 200mA | ||||
Supply Voltage | 12-30VDC (reverse-polarity protected) | ||||
Mechanical Specifications | |||||
Current Consumption | < 50mA at 24 VDC (no burden) | ||||
Material Exposed to Tank Atmosphere |
316 SS Rod: 1.4404 / 316L and PEEK Gasket at connection thread: Klingersil C-4400, 0.1” thick | ||||
Start-Up Time | < 6s | ||||
Cable Terminals | Screwless, cage clamp terminal block for stranded and solid wires AWG 22-14 *The usage of cable end sleeves with insulation collar is not recommended | ||||
Enclosure Material | Aluminum alloy EN AC-AISi9Cu3 (DIN EN 1706), Epoxy Spray (~70µm) | ||||
Enclosure Rating |
Standard: NEMA 6 | ||||
Measurement Specifications | |||||
Accuracy | ± 0.12” or 0.03% of measured distance, whichever is greatest | ||||
Specifications are subject to change without notice. | |||||
Repeatability | < .08” | ||||
Resolution | < .04” | ||||
Probe Type | 316 SS Rod: 1/4” | ||||
Probe Length [L] | 316 SS Rod: 4” - 240” (Length must be specified when ordering - The reference point is always the sealing surface of the connection thread - See dimensional drawings) | ||||
Top Dead Band | Configurable below 1.5” | ||||
Bottom Dead Band | Configurable above 1.5” |
Ref: Flo-corp.com
Contact us : sales@wmablog.com or visit to our E-Commerce
Download Datasheet: ChannelFlo™ OCRM Guided Wave Radar Open Channel Flow Meter