Bamo BAMOFLONIC Ultrasonic Flow Meter - Flow Meter Indonesia - Flow meter air, flowmeter solar, gas, Ultrasonic, Vortex, Electromagnetic

Breaking

Minggu, 20 Februari 2022

Bamo BAMOFLONIC Ultrasonic Flow Meter

Bamo BAMOFLONIC Ultrasonic Flow Meter applies propagation ultrasonic waves principle to measure the speed of a liquid, then to calculate the corresponding flow-rate. Therefore, It is convenient for liquids electrically conductive or not. Important: The liquid must be clear and homogeneous.
Bamo BAMOFLONIC Ultrasonic Flow Meter

The absence of a moving part ensures its operation without mechanical wear. All wet parts are of PSU or of HD-PE (Sealing: EPDM)


Bamo BAMOFLONIC Ultrasonic Flow Meter Features:

  • 7 models ND 10 to ND 50
  • Flow ranges from 0.3 up to 900 l/min
  • Analogue output: 0/4-20 mA
  • Digital output to set on site
  • Back-lighted display


Application:

Flow measurements on conductive and non-conductive liquids in various industrial, cosmetic and food applications.
Examples: Demineralized water, liquid cosmetics, bases, acids, etc.


Bamo BAMOFLONIC Ultrasonic Flow Meter Specification:

Power supply24VDC/3.6W
OutputsDigital output: to set as pulses (0.1 to 3000 ml/pulse) or empty tube alert, flowing back alarm, dosage, or min./max. flow alarm.
 Analogue output: 0/4 ... 20 mA, scalable
DisplayAlphanumeric back lighted LCD display
ConnexionConnector M12 -5 pins (supplied)
Accuracy±2 % of reading and ±3 mm/s
Repeatability≤0,5%
Liquid temperature limits:0... +80 °C for version in PSU, ND 10 to 25
 0... +50 °C for version in HD-PE, ND 32 to 50
Pressure limits16 bar max. at 20 °C (PSU, ND 10 & 15)
 10 bar max. at 20 °C (PSU, ND 20 & 25)
 7 bar max. at 20 °C (HD-PE, ND 32 to 50)
ProtectionIP 67 for PSU ND 10 to 25; IP 65 for HD-PE ND 32 to 50
FittingsBSP threads (standard)
 PVC Unions (see accessories)
 Other fittings on request: Straight tube, Clamp DIN 11864
MaterialsPSU (Polysulfone): ND 10 to 25; 2 EPDM flat seals
 HD-PE: ND 32 to 50; 2 EPDM flat seals
Options 
Digital inputTo start a dosage (Connector M12 - 8 pins)
Accuracy±1 % of reading and ±3 mm/s, ±6 mm/s for NB 10 – 3/8'' (according to VDI/VDE 2642)
Remote interfaceTo set all parameters (Adaptor USB/ RS485 with software), or remote display module



Download Data Sheet: Ultrasonic Flow-Meter BAMOFLONIC

Ref: bamo.eu