Dwyer TFM-LP Series Liquid Turbine Flow Meter - Flow Meter Indonesia - Flow meter air, flowmeter solar, gas, Ultrasonic, Vortex, Electromagnetic

Breaking

Selasa, 15 Februari 2022

Dwyer TFM-LP Series Liquid Turbine Flow Meter


Dwyer TFM-LP Series Liquid Turbine Flow Meter utilizes a turbine wheel and electro-optical detection to convert flow rates into a linear 0 to 5 VDC and pulsed output signal for recording and data logging. A power adapter or mating cable assembly is required for operation.
Dwyer TFM-LP Series Liquid Turbine Flow Meter

Turbine sensors with electrical transmission output for remote indication of liquid flow rate. Dwyer turbine flow transmitters are suitable for a wide variety of industrial, commercial, and laboratory flow applications. A power adapter or mating cable assembly is required for operation.

Dwyer TFM-LP Series Features

  • Rugged 316 SS body
  • High repeatability with patented microturbine design
  • Design accurately measures flow rates with no zero drift and no required maintenance

Application

  • Industrial flow monitoring
  • Commercial systems
  • Laboratory equipment


Dwyer TFM-LP Series Specification

ServiceClean liquids compatible with wetted materials.
Wetted Materials316 SS, acetal, sapphire, glass, epoxy, and fluoroelastomer.
Accuracy±1% of FS.
Linearity±1% of FS.
Repeatability±0.2% of FS.
Temperature Limits41 to 131°F (5 to 55°C); Storage: 32 to 158°F (0 to 70°C); Sensitivity: ±0.2% of FS per °C.
Pressure Limits500 psig (34.5 bar).
Process ConnectionCompression fitting
Power Requirements11.5 to 15 VDC.
Power Consumption35 mA @ 12 VDC.
Output Signal0 to 5 VDC: Minimum 2.5 kΩ load; Pulse: 7.5 VDC peak buffered square wave.
Electrical ConnectionsFour-pin power and signal connector. A power adapter or mating cable required for operation.
Enclosure RatingIP10 (NEMA 1).
Weight0.86 lb (390 g).
Agency ApprovalsCE.