| Flocorp CalFlo™ CFSG3 Flow and Temperature Thermal Mass |
Flocorp CALFLO™ CFSG3 Features and Benefits
- Switch-point factory set
- Simple commissioning
- Reliable and durable
- Water-based media
- No moving parts
- LED display for power and switching status
- Rugged design
- Maintenance-free
- 5-year warranty
Specifications
| TECHNICAL DATA | THREAD | 1/2“ - 14 NPT or G 1/2“ BSP | |||
| MEDIUM | Water-based | ELECTRICAL CONNECTION | integrated plug connection with PG9 fitting, 2 m oilflex cable 3 x 0,5 mm2 | ||
| SENSOR DATA | |||||
| ELECTRICAL DATA | |||||
| SET-POINT | factory-set 80 cm/s (other set-point on request) | ||||
| OPERATING VOLTAGE | 18 - 30 VDC incl. residual ripple | ||||
| MEDIUM TEMPERATURE | -20 °C to +80 °C | ||||
| CURRENT CONSUMPTION |
max. 150 mA pulsed | ||||
| AMBIENT TEMPERATURE | -20 °C to +70 °C | ||||
| PRESSURE | up to 100 bar (10000 KPa) | ||||
| INTERNAL CONSUMPTION |
Internal consumption approx. 1 W | ||||
| RESPONSE TIME | approx. 5 sec. | ||||
| SWITCHING CURRENT | £ 400 mA | ||||
| REPEATABILITY | < 2 % | ||||
| PROTECTIVE CIRCUIT | reverse polarity, short circuits and overload protection (ready for operation after correcting the short circuit) | ||||
| HYSTERESIS | approx. 10 % | ||||
| MECHANICAL DATA | |||||
| OPERATION READINESS | appprox. 10 sec. after applying the operating voltage | ||||
| PROTECTION CLASS | IP 65 | ||||
| ELECTRICAL OUTPUT | n.o. (closer) currentless | ||||
| MATERIAL HOUSING | PBTP, glass fibre reinforced (Ultradur®) | ||||
| SENSOR PIPE | stainless steel AISI 303 | ELECTRICAL OUTPUT INDICATION | LED = switch state red / green | ||
| Specifications are subject to change without notice. | |||||
Download Datasheet: CalFlo™ CFSG3 Flow and Temperature Thermal Mass Flow Switch
Ref: Flo-corp.com