| Heinrich K09 Low Volume |
Heinrich K09 Low Volume Applications
Approvals and certificates
- Explosion protection: in preparation (for mech. instrument)
- Contacts PTB 00 ATEX 2128 X (with limit switches)
- Ignition category: II 2G EEx ia IIC T6-T4
- CE-marking: Ex-guidelines 94/9/EG
- EMC: EMC-guidelines 2004/108/EG
- PED: 97/23/EG
Heinrich K09 Low Volume Technical Data:
| Ranges: | ||
| Water 20 °C, min: | 0,02-0,25 l/h, max:10-100 l/h | |
| Air 20 °C, 1,2 bar abs., min: | 2-20 Nl/h, max:300-3000 Nl/h | |
| Electronic output: (Option) | ||
| 1 inductive switch, mono- or bistable | ||
| Mono-stable RC 10/15-14-N0 | ||
| Bi- stable RC 10/15-14-N3 | ||
| Make: | Pepperl+Fuchs, | |
| Accuracy: | ||
| Reference conditions: | water 20 °C (air 20 °C, 1,2 bar abs) | |
| Measuring error: | ± 3 % qG= 50% acc. VDE/VDI 3513 Bl. 2 | |
| Repeatability | ± 1,0 % of the upper range value | |
| Applications: | ||
| Metering of liquid products with suitable viscosity, free of solids, not clog, and do not tend to form deposits. | ||
| Gases with linear flow characteristics and adequate inlet pressure. | ||
| Ambient conditions: | ||
| Ambient temperature -20°C up to +100°C (risk of frost fracture!) (with switch +70°C) | ||
| Ingress protection: | IP 65 (EN60529) | |
| Product conditions | ||
| without switch: | -20°C up to +100°C | |
| with switch: | -20°C up to +70°C | |
| Ingress protection: | IP 65 (EN60529) | |
| Max. pressure: | PN 10 | |
| All pressure data refer to liquids without danger potential and proper and stress-free installation of the equipment | ||
Download Catalog: Low Volume variable area with glass tube Model K09 Heinrich
Ref: Heinrichs.com