McCROMETER Ultra Mag Electromagnetic Flow Meter |
Use in hazardous locations :
- Class 1, Division 2, Groups A-D, T5
- Class 2, Zone 2, Groups A-D, T5
- Non-intrusive measurement
- NSF-approved, fusion-bonded epoxy liner: the UltraLiner
- Signal converter (can be meter mounted or remote mounted up to 500 ft. away)
- Meter is wet calibrated in NIST traceable calibration facility
- Forward and reverse flow outputs and totalization
McCROMETER Ultra Mag Features
Performance Advantage
- Needs only 1 pipe diameter upstream of most flow disturbers
- No obstruction to the flow
- No moving parts to wear or break
- Maintenance free
- Worry-free accurate measurement
- Debris or solids will not clog the meter
- No head loss
- Bi-directional flow
- Empty pipe detection
- Unaffected by changes in density and viscosity
- No risk of liner delamination or separation
- Wide flow range
- Separated power and signal cables
Typical Advantage
Industrial
- Raw Water
- Chilled Water
- Cooling Water
- Process Control
- Effluent Wastewater
Clean Water
- Well Water
- Potable Water
- Pump Stations
- Rate-of-Flow Control
- Raw Water Transmission
Wastewater
- Influent
- Effluent
- Reclaimed
- Lift Stations
- Waste Activated
- Sludge
- Return Activated
- Sludge
McCROMETER Ultra Mag Specifications
Pipe Sizes
- 2" to 48”
Flow Direction Measurement
- Forward and reverse flow indication and forward, reverse, net totalization are standard with all meters
Accuracy
- Plus or minus 0.5% of actual flow (battery powered is ±1% of flow)
IMPORTANT NOTICE ON FLOW METER ACCURACY : The flow meter, the cable and the electronics are factory calibrated for accuracy as a single unit. Changing the cable length with the Splice Kit changes the accuracy of the meter and invalidates the calibration certificate.
Accuracy Tests
- 5-point wet flow calibration of every complete flow tube with its signal converter. If desired, the tests can be witnessed by the customer. The McCrometer test facilities are traceable to the National Institute of Standards & Technology. Uncertainty relative to flow is ±0.15%
Pipe Run Requirements
- 2” & 3” : wafer style 3D upstream / 1D downstream
- 2” and larger flanged : 1D upstream / 0D downstream
Repeatability
- ±0.05% or ±.0008ft/s (±0.25mm/s), whichever is greater
Conductivity
- 5 µs/cm
Liner
- UltraLiner NSF approved, fusion bonded epoxy
Electrodes
- Type 316 stainless steel, others optional
Electrical Connections
- Compression gland seals
- Quick-Connect
IP Rating
- Standard model
Quick Connect (NEMA 6P/IP68 with remote converter)
Compression gland seals (NEMA 6P/IP68 with remote converter) - HL model
Quick Connect (IP67)
Compression gland seals (IP67)
Sensor Submersibility Depth
- With standard strain relief cable : 9 m (30 ft.)
- With optional quick connect cable : 1.8 m (6 ft.)
Head Loss
- None. No obstruction in line and no moving parts
Pressure Range
- 150 PSI maximum working pressure (UM06); 300 PSI maximum working pressure (UM08)
Velocity Range
- .2 to 32 FPS
Temperature Range
- Sensor Operating : -10 to 60°C (14 to 140°F)
- Sensor Storage : -15 to 60°C (5 to 140° F)
Certifications and Approvals
- Standard Model
ISO 9001:2015 certified quality management system
Certified by MET to UL 61010-1 - HL Model
ISO 9001:2015 certified quality management system
Certified by MET to UL 61010-1 and MET C22.2 No. 61010-1-04
Class I, Division 2, Groups A-D, T5
Class I, Zone 2, IIC T5
System Options
- Hastelloy® electrodes
- Additional sensor cable up to 475’
- Annual verification / calibration
- Stainless steel ID tag
Meter Options
- DC powered converter (10-35 VDC, 21 W)
- Meter mounted converter
- Extended warranty
- Hastelloy® electrodes
- ANSI or DIN flanges
- Special lay lengths, including ISO standard lay lengths
- Quick Connect cable fittings
- Converter sun shield
- HART® Converter
- Smart Output™ (Sensus or Itron compatible)
- Battery or battery-solar powered converter
Download Datasheet: McCROMETER Ultra Mag Electromagnetic Flow Meter