Signet 2580 FlowtraMag is a full-bore plastic PVC in line style magnetic flowmeter. The PVC body with titanium or Hastelloy® C electrodes has no moving parts, and is two to three times lighter in weight compared to traditional metal magmeters on the market. It is designed for high accuracy flow measurement in short pipe runs, making it an ideal solution for industrial applications where performance and ease of use are important.
Signet 2580 FlowtraMag PVC Electromagnetic Flow Meter |
The FlowtraMag design is factory calibrated with certificate at ±1% of reading accuracy. It is offered in corrosion resistant materials to provide long-term reliability with minimal maintenance costs. The LED indicators show at-a-glance system status, including normal operation, zero flow and partially filled pipe detection.
The flow meter provides rthee different outputs; field selectable frequency or digital (S3L) as well as analog 4 to 20 mA. The FlowtraMag is capable of temperature readings of the media using the Signet 0252 Configuration Tool or GF Config Tool Bluetooth® app. The GF Config Tool Bluetooth® app supports iOS and Android for simple on-the-fly user configuration.
These versatile, easy-to-install meters deliver accurate flow measurement in pipe sizes of DN25 (1 in.), DN50 (2 in.) and DN100 (4 in.), optimized for performance in short pipe runs often associated with final effluent lines, well heads and water treatment skids.
Signet 2580 FlowtraMag Features
- No moving parts
- Lighter in weight compared to traditional metal magmeters
- Reduced straight run requirements, ideal for final effluent lines, wellheads and skids
- Factory calibrated with certificate (±1% of reading accuracy)
- Partially filled pipe detection status indicator
- Visual LED indicators make sensor status clear and easy to read
- Reverse flow direction configurable with 0252 Configuration Tool or GF Config Tool Bluetooth® App
- Capable of temperature readings of the media using the 0252 Configuration Tool or GF Config Tool Bluetooth® App
- One device with three different outputs: field selectable Frequency or Digital (S³L), and analog 4 to 20 mA
- On-the-fly configuration with GF Config Tool Bluetooth® App
- Bluetooth® 4.2 capable, support iOS and Android for simple user configuration
Applications
- Chemical Processing/Production
- Cooling Tower
- Filtration Systems
- Water and Wastewater Treatment
- Municipal and Industrial Water Distribution
- Pool and Aquatics
- Process Control, Water Process Flow
- Reverse Osmosis
- Scrubber Systems
- Metal Recovery and Landfill Leachate
- Mining
Specifications
General | |||
Pipe Size Range | DN25, DN50, DN100 | in., 2 in., 4 in. | |
Flow Range Titanium or Hastelloy C | 0.02 to 10 m/s | 0.07 to 33 ft/s | |
DN25 (1") | 0.53 LPM to 266.35 LPM | 0.14 to 70.36 GPM | |
DN50 (2") | 2.23 LPM to 1112.60 LPM | 0.59 to 293.92 GPM | |
DN100 (4") | 8.72 LPM to 4357.83 LPM | 2.30 to 1151.22 GPM | |
Minimum Conductivity | μS/cm – water based | ||
Power Cable Wire | 7.6 m (25 ft) 2-conductor shielded | ||
Output Cable Wire | 7.6 m (25 ft) 5-conductor shielded | ||
Cable wires may be extended up to 300 m (1000 ft), special order only | |||
Wetted Materials | |||
Flow Tube Body | PVC | ||
Electrode | Titanium, grade 2 or Hastelloy C-276 | ||
O-rings | FKM | ||
Performance | |||
Accuracy | ± 1% of reading plus ± 0.01 m/s (0.033 ft/s), reference condition 50 μS/cm and water based | ||
Repeatability | ± 0.5% of reading @ 25 °C (77 °F) | ||
Low Flow Cutoff | 0.02 m/s (0.07 ft/s) (adjustable via 0252 Confi guration Tool or GF Confi g Tool App) | ||
Electrical | |||
DC Power (Functional Rating) | 24 VDC, max 24 W (12 to 32 VDC) | ||
Reverse Polarity Protected | Up to 35 VDC | ||
Over-Voltage Maximum Rating | 35 VDC | ||
Current Output | |||
Passive (low power) | 4 to 20 mA per ANSI-ISA 50.00.01 Class H | ||
Active Output | 4 to 20 mA | ||
Passive Loop Voltage | 12 to 32 VDC | ||
Loop Accuracy | ±32 μA (@ 25 °C @ 24 VDC) | ||
Loop Resolution | 5 μA | ||
Loop Span | 3.8 mA to 21 mA | ||
Error Condition | None, 3.6 mA or 22 mA | ||
Max. Cable | 300 m (1000 ft) | ||
Max. Loop Resistance | 600 Ω @ 24 VDC | ||
Compatible with PLC, PC or similar equipment | |||
Frequency Output | |||
Frequency | 5 to 24 VDC, 50 mA max. | ||
Frequency Range | 0 to 1500 Hz | ||
Max. Cable | 300 m (1000 ft) | ||
Max. Pull-up Voltage | 30 VDC, 10k pull-up recommended | ||
Compatible with Signet 8900, 9900, 9950, and 0486 Profi bus Concentrator | |||
Digital (S3L) Output | |||
Digital (S3L) | 4.5 to 5.5 VDC | ||
Serial ASCII, TTL level 9600 bps Compatible with Signet 8900, 9900, 9950 and 0486 Profi bus Concentrator | |||
Max. Cable Length | Application dependent | ||
Environmental Requirements | |||
Enclosure | NEMA 4X / IP65 | ||
Relative Humidity | 0 to 95% non-condensing | ||
Storage Temperature | -10 °C to 60 °C (14 °F to 140 °F) | ||
Operating Temperature | |||
Ambient | -10 °C to 60 °C | 14 °F to 140 °F | |
Media | 0 °C to 60 °C | 32 °F to 140 °F | |
UL Environmental Rating | UL 50, Type 6P Storage | ||
Altitude | 4,000 m | 13,123 ft | |
Pressure/Temperature Ratings | |||
Maximum Operating Pressure | 10 bar @ 23 °C (145 psi @ 73 °F) | ||
DN25 (1") and DN50 (2") | 3.5 bar @ 60 °C (51 psi @ 140 °F) | ||
DN100 (4") | 2.27 bar @ 60 °C (33 psi @ 140 °F) | ||
Shipping Weight -Titanium or Hastelloy C | |||
DN25 (1") | 3.4 kg | 7.5 lbs | |
DN50 (2") | 4.5 kg | 9.9 lbs | |
DN100 (4") | 8.3 kg | 18.3 lbs | |
Standards and Approvals | |||
CE, FCC, NSF (Titanium only, does not include fl ange gaskets) | |||
UL, CUL Recognized Component | |||
RoHS compliant, China RoHS | |||
Manufactured under ISO 9001 for Quality, ISO 14001 for Environmental Management and OHSAS 18001 for Occupational Health and Safety. |
Download Datasheet : Signet 2580 FlowtraMag® Meter
Reference : gfps.com